Table of ue gas exhaust duct lengths
S1 = Air intake
S2 = Flue gas exhaust
TYPE C13
TYPE C33 TYPE C53
TYPE C33 TYPE C33
FLUE TYPE
Maximum Extension Exhaust-air (m)
Diameter of pipe
(mm)
ALTEAS ONE + NET
GENUS ONE + WIFI
24 30 35
MIN MAX MIN MAX MIN MAX
Coaxial
System
C13
C33
C43
1 8 1 5 1 5
ø 60/100 (*)
B33 1 8 1 5 1 5
C13
C33
C43
1 21 1 14 1 14
ø 80/125
B33 1 21 1 14 1 14
Twin-pipe
System
S1 = S2
ø 80/80
C13 1,5 = 1,5 32 = 32 1,5 = 1,5 23 = 23 1,5 = 1,5 24 = 24
C33 1,5 = 1,5 38 = 38 1,5 = 1,5 28 = 28 1,5 = 1,5 29 = 29
C43 1,5 = 1,5 32 = 32 1,5 = 1,5 23 = 23 1,5 = 1,5 24 = 24
S1 + S2
C53
C83
2,5 64 2,5 46 2,5 48 ø 80/80
B23 1,5 64 0,5 46 0,5 48 ø 80
S1 = S2 - Air intake and ue gas exhaust equal lengths
S1 + S2 - Air intake and ue gas exhaust unequal lengths

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ALTEAS ONE+ NET and is the answer not in the manual?

Ariston ALTEAS ONE+ NET Specifications

General IconGeneral
TypeCondensing Boiler
Energy RatingA
Modulation1:10
NOx EmissionsClass 6
Efficiency94%
Output24 kW
ControlTouchscreen
Fuel TypeNatural Gas
ConnectivityWi-Fi
Heating Capacity24 kW
DHW Flow RateUp to 14.3 l/min