Page #10 background imageLoading...
Page #10 background image
Description
10 / EN
Domestic hot water time schedule profile
0 2 4 6 8 10 12 16 20 14 18 22 24
35,0° 35,0° 60,0°60,0°
Fig. 11
If the system is configured for producing domestic hot water,
the domestic hot water time schedule profile is displayed.
Domestic hot water heat pump mode
Fr 4-JUN 12:30
Internal temperature
20°
Required temperature
21°
Outside air temperature
16°
Operation mode
55°C
Fig. 12
If there is a domestic hot water heat pump, the products
operating mode and the set-point temperature of the water
are shown.
For the meaning of the icons, refer to the paragraph Complete
home page.
2.6 Stand-by page
10°
12:00
21
,0
°
Monday 1 March 2021
Fig. 13
2.7 Basic functions
Manual room temperature adjustment
The operating mode of the zone associated with the device is
set to MANUAL (1).
Turn the selector to select the temperature value indicated on
the display using the movable cursor near the ring. Press the
selector to confirm.
The display shows the set temperature.
30
21°
SALOTTO
,5
°C
5
19
,0
°
18:30 11/10/2020
10°
1,5 bar
50%
1
Fig. 14
Room temperature adjustment in programmed mode
The operating mode of the zone associated with the device
is set to PROGRAMMED (2). During operation in scheduled
programming mode, the set room temperature can be
changed temporarily.
Turn the selector to select the temperature value indicated
using the movable cursor near the ring. Press the selector to
confirm.
The display shows the set temperature.
Turn the selector to set the time until which the change must
be maintained.
Press the selector to confirm. The (3) symbol appears on the
display.
The system interface will maintain the temperature value
until the set time, after which the pre-set room temperature
is restored.
30
21°
SALOTTO
,5
°C
5
19
,0
°
18:30 11/10/2020
10°
1,5 bar
50%
Fino alle 20:00
3
2
Fig. 15
Room temperature adjustment with AUTO function on
If the heating hot water temperature does not match the
desired value, it can be increased or decreased via the “Heating
Settings”. The correction bar will appear on the display.
Press the selector to confirm, or press the back button to return
to the previous screen without saving.
2.8 Operation
The main page of the system interface can be customised.
The main page can be used to check the time, date, operating
mode, the set or measured temperatures, the time scheduling
and the active energy sources.

Table of Contents

Other manuals for Ariston NIMBUS M NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston NIMBUS M NET and is the answer not in the manual?

Ariston NIMBUS M NET Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR32
Power SupplyElectric
Power Supply Voltage230 V
ConnectivityWi-Fi
Heating Capacity6 kW