User menu
19 / EN
3.4 Holiday function
The “Holiday function” allows for:
Deactivating the heating, cooling and domestic hot
water modes during the holiday period.
Setting the system to DHW and anti-frost protection
mode until the set date.
Holiday function
When do you plan to return from your vacation?
During your absence the temperature will be kept at
a lower level with a significant energy saving
30
/ 12 / 2021
Save
Fig. 43
Turn the selector
to change the value of the
selected field.
Press the selector
to skip to the next item
To change a previously set value, press the “Back” button
.
Holiday function
When do you plan to return from your vacation?
During your absence the temperature will be kept at
a lower level with a significant energy saving
30 / 12 / 2021
Save
Fig. 44
Navigate to “Save” and press the selector
.
The holiday function is activated. The system will
automatically turn on again at hours 00:01 of the
day 30/12/2021. The antifreeze function is active.
Fig. 45
A message will appear to confirm the settings.
3.5 Operating mode
Allows for selecting the systems operating mode:
"Summer": domestic hot water production, space
heating off.
"Winter": domestic hot water production and space
heating on.
"Heating only": indirect cylinder heating off (where
present).
Cool mode and Domestic hot water“: domestic hot
water production and cooling.
Only Cool mode“: indirect cylinder heating off
(where present).
"OFF": system off, anti-frost function enabled.
3.6 DHW settings
The “DHW settings” function allows for selecting:
The desired water temperature.
The operating mode for domestic hot water production.
The thermal sanitisation function for the DHW storage
tank (if present).
DHW settings
DHW comfort setpoint temp.
55°C
DHW reduced setpoint temp. 35°C
Comfort function Disabled
Tank charge mode Standard
Domestic hot water boost
>
Thermal cleanse function
>
Fig. 46
"DHW comfort setpoint temp.": setting of the
temperature set-point for the comfort slot.
"DHW reduced setpoint temp.": setting of the
temperature set-point for the reduced-temperature
slot.
"Comfort Function": setting of the operating mode
for domestic hot water production (“Disabled”/”Time
Based”/”Always active”).
"Tank charge mode": setting of the cylinder filling
mode in hybrid systems (“Standard”/”Fast”).
"Domestic hot water boost": fast filling of the cylinder
(available for heating heat pumps and domestic hot
water).
"Thermal cleanse function": see next paragraph.
"DHW time program": direct access to the DHW time
scheduling menu.

Table of Contents

Other manuals for Ariston NIMBUS M NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston NIMBUS M NET and is the answer not in the manual?

Ariston NIMBUS M NET Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR32
Power SupplyElectric
Power Supply Voltage230 V
ConnectivityWi-Fi
Heating Capacity6 kW