User menu
26 / EN
– "DHW operation mode": the parameter sets the DHW
production mode.
– "Standard": domestic hot water is produced using
both the heat pump and the secondary heating
source for integration.
– "Green Mode": the heating elements are excluded
from the production of domestic hot water and are
activated only in case of a heat pump malfunction.
Domestic hot water production follows the auxiliary
time scheduling.
– "HC - HP": domestic hot water production is only
allowed when the EDF signal is active and according
to the cheapest electricity rate. To configure the EDF
signal of the heat pump, see the product manual.
– "HC - HP 40": domestic hot water production is
only allowed when the EDF signal is active; when the
signal is not active, the DHW cylinder is maintained
at the minimum temperature of 40°C. To configure
the EDF signal of the heat pump, see the product
manual.
3.11.6 Hybrid
This menu is available only if a hybrid product is installed. For
further information, see the product manual.
Hybrid Energy Manager
Quiet mode
>
Energy Manager logic Max Ecology
Hybrid Mode
Auto
Energy tariff settings
>
Fig. 68
– "Quiet mode": refer to the paragraph “Heat Pump”.
– "Energy Manager logic": the parameter allows to
select the operation of the hybrid system based on the
“Max Saving” or “Max Ecology” values.
– "Hybrid Mode": the parameter allows to choose the
heat generators to be enabled in the production of
heat.
– “Auto”: both the heat pump and the boiler are used
to produce heat according to the setting of the
previous parameter.
– “Only boiler”: only the boiler is used for the
production of heat.
– “Only HP”: only the heat pump is used for the
production of heat.
– "Energy tariff settings": this menu allows you to set
the price for gas and electricity, as well as a reduced
electricity rate. The prices are expressed in cents.