Astraada DRV-24 frequency inverters Function Parameters
36
Functio
n code
Name
Detailed instruction of parameters
Defaul
t value
Modify
Setting range: 0.0~3600.0s (valid when
P01.19=2)
P01.21
Restart
after power
off
This function can enable the inverter start or
not after the power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the
inverter will run automatically after waiting for
the time defined by P01.22.
0
P01.22
The waiting
time of
restart after
power off
The function determines the waiting time
before the automatic running of the inverter
when powering off and then powering on.
Setting range: 0.0~3600.0s (valid when
P01.21=1)
1.0s
P01.23
Start delay
time
The function determines the brake release
after the running command is given, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
0.0s
P01.24
Delay of the
stopping
speed
Setting range: 0.0~100.0s
0.0s
P01.25
0Hz
output
Select the 0Hz output of the inverter.
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
P02 Group Motor 1
P02.01
Rated
power of
asynchrono
us motor
0.1~3000.0kW
Depen
d on