Astraada DRV-24 frequency inverters Function Parameters
36
Detailed instruction of parameters
Setting range: 0.0~3600.0s (valid when
P01.19=2)
This function can enable the inverter start or
not after the power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the
inverter will run automatically after waiting for
the time defined by P01.22.
The waiting
time of
restart after
power off
The function determines the waiting time
before the automatic running of the inverter
when powering off and then powering on.
Setting range: 0.0~3600.0s (valid when
P01.21=1)
The function determines the brake release
after the running command is given, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
Delay of the
stopping
speed
Setting range: 0.0~100.0s
Select the 0Hz output of the inverter.
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
Rated
power of
asynchrono
us motor