Astraada DRV-24 frequency inverters Function Parameters
40
Detailed instruction of parameters
parameter of the current loop which affects
the dynamic response speed and control
accuracy directly. Generally, users do not need
to change the default value;
Only apply to the vector control mode without
PG 0 (P00.00=0).
Setting range:0~65535
Current
loop
integral
coefficient I
This parameter is used to enable the torque
control mode, and set the torque setting
means.
0:Torque control is invalid
1:Keypad setting torque(P03.12)
2:Analog AI1 setting torque
3:Analog AI2 setting torque
4:Analog AI3 setting torque
5:Pulse frequency HDI setting torque
6: Multi-step torque setting
7:MODBUS communication setting torque
8~10: Reserved
Note: Setting mode 2~7, 100% corresponds to
3 times of the motor rated current
Setting range: -300.0%~300.0%(motor rated
current)
Setting
source of
forward
rotation
upper-limit
frequency
in torque
control
0:keypad setting upper-limit frequency(P03.16
sets P03.14, P03.17 sets P03.15)
1:Analog AI1 setting upper-limit frequency
2:Analog AI2 setting upper-limit frequency
3:Analog AI3 setting upper-limit frequency
4:Pulse frequency HDI setting upper-limit
frequency
5:Multi-step setting upper-limit frequency
6:MODBUS communication setting upper-limit
frequency
7~9: Reserved
Note: setting method 1~9, 100% corresponds
to the maximum frequency
Setting
source of
reverse
rotation
upper-limit
frequency
in torque
control
Torque
control
forward
rotation
This function is used to set the upper limit of
the frequency. P03.16 sets the value of P03.14;
P03.17 sets the value of P03.15.
Setting range:0.00 Hz~P00.03 (the Max. output