Astraada DRV-24 frequency inverters Function Parameters
73
Functio
n code
Name
Detailed instruction of parameters
Defaul
t value
Modify
P10.21
The running
time of
stage 9
S4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
step
0
1
2
3
4
5
6
7
S1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
S3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
S4
ON
ON
ON
ON
ON
ON
ON
ON
step
8
9
10
11
12
13
14
15
Setting range of P10.(2n,1<n<17):
-100.0~100.0%
Setting range of P10.(2n+1,
1<n<17):0.0~6553.5s(min)
0.0s
P10.22
Multi-step
speed 10
0.0%
P10.23
The running
time of
stage 10
0.0s
P10.24
Multi-step
speed 11
0.0%
P10.25
The running
time of
stage 11
0.0s
P10.26
Multi-step
speed 12
0.0%
P10.27
The running
time of
stage 12
0.0s
P10.28
Multi-step
speed 13
0.0%
P10.29
The running
time of
stage 13
0.0s
P10.30
Multi-step
speed 14
0.0%
P10.31
The running
time of
stage 14
0.0s
P10.32
Multi-step
speed 15
0.0%
P10.33
The running
time of
stage 15
0.0s
P10.34
Simple PLC
0~7 stage
ACC/DEC
time
selection
Below is the detailed instruction:
Functio
n code
Binary bit
Step
ACC/
DEC
0
ACC/
DEC
1
ACC/
DEC
2
ACC/
DEC
3
P10.34
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
BIT1
BIT1
5
00
01
10
11
0x0000
P10.35
Simple PLC
8~15 stage
ACC/DEC
time
selection
0x0000