Viron eQ Salt Chlorinator With Bluetooth | Installation and Operation Manual
Page 11
DO NOT install probes upside down as probes
contain a reference gell that can separate and
flow away from the probe tip due to prolonged
positioning and gravity.
Ideally the Acid Injection points should always be
AFTER the cell.
A pH and/or ORP sensor should be installed at
least 30 cm away from any pipe elbow to prevent
turbulent flow.
Acid
Injection
Point
Proper and Improper Sensor Orientations
Figure 11. pH and ORP Sensor Installation
Section 6. Pool Chemistry and
Balance the Pool
6.1 Water Chemistry Table
Test and maintain correct water balance
throughout the season, according to the table.