Viron eQ Salt Chlorinator With Bluetooth | Installation and Operation Manual
Page 9
Section 5. Chemical Connections
WARNING
• Never mix chemicals
• Chemicals must be stored in accordance with Relevant Standards
and Dangerous Goods Codes. Consult your authorized builder or
pool shop technician for advice.
• When handling acid, safety gloves and goggles should always
be used.
• Chemicals must be at least 1 m horizontally from control unit in
a well ventilated area to avoid corrosive damage.
• For best results a ratio of 2:1 is recommended.
The unit is designed to run with 2 PARTS WATER,
1 PART ACID (2.1 RATIO). Proper ratio should
always be followed as the machine’s dosing rate is
formulated around the diluted solution. Using neat
acid can lead to overdosing the pH level.
5.1 Chemical Placement
To avoid potential corrosion issues, the liquid
acid drum shouldn’t be placed underneath any
equipment.
To Pool
Line
To Pool
Line
Chemical
Drum
Incorrect Installation
Timer
Clock
Pool
Mode
Spa
Mode
Viron eQuilibrium
Timer
Clock
Pool
Mode
Spa
Mode
Viron eQuilibrium
Figure 7. Chemical Placement
5.2 Placement of Control Unit
If the Viron eQ Salt Chlorinator is installed in an
enclosure or shed, the liquid acid drum should
ideally be stored outside of the enclosure or shed.
The Viron eQ Salt Chlorinator needs to be kept
away from the elements to protect the longevity
and function of the components.
Timer
Clock
Pool
Mode
Spa
Mode
Viron eQuilibrium
Timer
Clock
Pool
Mode
Spa
Mode
Viron eQuilibrium
Figure 8. Viron eQ Salt Chlorinator Shelter
Requirements
5.3 Chemical Line Connections
5.3.1 Install the PVC Tube
To avoid loss of water from the system, close all
stop valves before cutting any lines.
• Clear Tube - 4m to be cut to required length
(installation dependant)
• White Tube -to be inserted in the Container lid
(2 lids are supplied with the kit to suit either a
25/15 ltr or a 5 ltr container) The tube is supplied
to suit to a length to suit a 25ltr container. For
use on 15 ltr containers, the white tube needs
to be cut to approx. 265mm long. For use on 5
ltr containers the white tube needs to be cut to
approx. 250mm long.
VENT
Wall
PUMP
Chlorine
bottle
Keep 5 - 10 mm clearance
from bottom of container
Non-return
valve
Figure 9. Acid Container Line Connections
Tubes to be
cut to suit
installation
(Tube
supplied in
kit)
Longer
spigot to
pump
Shorter
spigot to
wall vent
PUMP
VENT
Figure 10. Acid Cap Tube Fitting and Venting