Loading...
QSG_F28+.394.00_EN_01 / 2019-02-25
36 / 42
PARAMETERS menu
Use this menu to configure the measurement cycle associated to each test program.
TYPE : LEAK TEST
COUPL. A 0.0 s
2.0 s
2.0 s
2.0 s
1.0 s
bar
5.00
FILL TIME
STAB TIME
TEST TIME
DUMP TIME
Press. UNIT
Max FILL
PARAM / Pr 001
Default parameters of the LEAK type tests
Label Parameter Description
COUPL. A or COUPL. B
Coupling time Required times when instrument manage
automatic jigs
FILL TIME
Fill time Time to pressurise the part under test
STAB TIME
Stabilization time Time to stabilise the pressure on the test and
reference parts
TEST TIME
Test time Time for leak measurement
DUMP TIME
Dump time Time to vent the part to atmosphere
Press. UNIT
Pressure units Pressure unit (bar, mbar,PSI, Pa,kPa,MPa)
Max FILL
Maximum fill pressure Maximum level of the fill pressure
Min FILL
Minimum fill pressure Minimum level of the fill pressure
LeakUnit
Reject unit Measurement units
Test FAIL
Test fail Upper leak rate limit for the test part. Above this
limit, the part is considered as defective.
Ref. FAIL
Reference fail Reference part reject level
FUNCTIONS
Functions Access to additional functions
Additional functions
Label Function Description
24V OUTPUTS
Auxiliaries output 24 V Available outputs for external automatism
ABSOLUTE
Absolute Display the absolute value of the results
ATF
ATF time Absorb the important leak variations at the
defined time
ATR0/ATR1 /
ATR2/ATR3
ATR 0 - 3 Specific filters on leak measurement
AUTO CONNECT
Automatic connector Function to manage automatic jigs
BUZZER
Buzzer Buzzer activation configuration
CODE READER
Bar code reader Bar code configuration
CUT OFF
Cut off All the measurements that are lower than the
configured rate have the value 0
DISP. OPT.
Display option Display of an additional information on a second
line
DISPLAY MODE
Display Mode Leak measurement resolution

Related product manuals