BLM 3750 User Guide Executing a Free Test
9836 3078 01 Edition 2.0 31 (78)
The results of the tests run on the tool are displayed in the Results area; the statistics are calculated in real
time and updated every time a test is completed.
The Cm / Cmk statistics begin to indicate the results when at least 10 tests have been performed.
NOTE: The first test is marked as test number 0, and it is not included in the statistics and in the
test report.
During the test execution is not possible to change any parameter in the test window. Click on Abort Test
to quit the test and change the parameters to execute a different test. If at least 10 tests have been
performed, the Test Report icon is activated. Click on it to show, and possibly print, the report. See the
chapter Test report for details.
When aborting a test and starting it again without changing any parameter, the software ask to continue
the previous test: If yes the test results present are not deleted and the previous test continue), otherwise
the test results present are deleted and a new set of test is started.
area (test n. 0 is
not considered)
Abort test
Display graph