BLM 3750 User Guide User Interfaces
9836 3078 01 Edition 2.0 25 (78)
Flashing code
Fault description
Problem
1 flash
Battery voltage too low
Battery not connected or failing, or output fuse burnt
2 flashes
Battery voltage too high
Wrong battery or battery charger fault
3 flashes
Charge time exceeding the limit
Wrong battery or battery fault
4 flashes
Input AC power missing
Input AC power non connected or input fuse burnt
5 flashes
Overheat
Temperature too high, fan fault
6 flashes
Possible battery damage
Battery voltage < 20V and battery charger turned off
3.11 Hardware Protection Key: System Backup
The BLM 3750 bench contains a hardware protection USB key; which provides the following features:
System backup: Test bench settings and calibration data.
NOTE: Personal documents are not saved in the backup! Traces saved during tests
on the bench are included in the backup only if saved in the default C:\BLM
3860\3860Front folder
Hardware protection function (if the key is not present the bench software is not started)
Special functions enabling
User profile
NOTE: The user profile provided by hardware protection key does not have
access to the bench calibration and advanced bench settings
This key performs different backups:
Daily backup
Weekly backup
Factory backup