Working with Torque Supervisor BLM 3750 User Guide
58 (78) 9836 3078 01 Edition 2.0
After each test the following window is shown:
The torque value measured by the bench is shown; the torque value read by the tool controlled must be
entered manually. Enter the torque measured by the tool controller value and click on Enter to confirm.
If the difference between of the two values exceeds a certain percentage (defined into the bench settings) a
warning message is shown:
At the end of the tests the old and new calibration values are displayed:
The Old Coefficient field shows the actual calibration value; if the actual calibration value is not stored in
Torque Supervisor, the Edit Old button is shown and the value must be entered manually: