FlexiROC T30 R 5 Safety Functions
22 No: 3133793291.1.3133851403 en-US
!
NOTE: Disable the automatic fire suppression system when steam-cleaning, hi-pres-
sure washing, welding, battery charging and starting with auxiliary battery.
To disconnect the automatic fire suppression system, remove fuse FSB1 located near the
battery. Check all electrical functions when work is done.
The fire fighting system suppresses fire over the following areas:
n Over and around the engine
n Over and around the fuel tank
Large quantities of flammable materials cannot be suppressed by the automatic fire sup-
pression system. Use other methods to suppress residual fires.
See Reference Documentation
OEM instructions for automatic fire suppression system
5.3.3 Description of Fire Extinguishers
Make sure that the machine is equipped with approved portable fire extinguishers in accor-
dance with the local regulations and laws that apply. The machine is equipped with desig-
nated locations for the fire extinguishers.
Class Type of Fire
A Fires of common materials that burn with both
flames and glow (for example, most interior mate-
rials)
B Fluid fires such as gasoline and oil
C Gas fires
Table1: Classification of Fires
Follow the instructions on the fire extinguisher.
5.3.4 Location of Fire Extinguishers
!
NOTE: If the fire extinguisher has been used then, it must be replaced with a new one
immediately.