Control panel
Step Action
1 Switch on the voltage. Voltage on LED (6) lights up.
2 Close the condensate drain valves (see the section Cooling and condensate system).
3 Open the air outlet valve.
4 Check the oil level indicator (see the section Oil change). The pointer should be in the
green range or orange range.
5 On compressors with integrated dryer, check that the by-pass valve is closed and that the
inlet and outlet valves of the dryer are open (see the section Initial start-up).
Open the water shut-off valves and the water regulating valve.
5.3 Starting
Warning
The operator must apply all relevant Safety precautions.
On Full-Feature compressors, switch on the voltage 4 hours before starting in order to
energise the crankcase heater of the refrigerant compressor.
Instruction book
82 2920 1475 06