33
E386 7inc x cm Trend deviation alarm, the subgroup
CM mean value has increased 7 times
consecutively.
E387 7dec x cm Trend deviation alarm, the subgroup
CM mean value has decreased 7 times
consecutively.
E388 7inc r cm Trend deviation alarm, the subgroup
CM range value has increased 7 times
consecutively.
E389 7dec r cm Trend deviation alarm, the subgroup
torque range value has decreased 7
times consecutively.
E390 7above x cm Trend deviation alarm, the subgroup CM
mean value has been above the average
mean value of the average of the latest
ten subgroups 7 times consecutively.
E391 7below x cm Trend deviation alarm, the subgroup
torque mean value has been below
the average mean value of the average
of the latest ten subgroups 7 times
consecutively.
E392 7above r cm Trend deviation alarm, the subgroup CM
range value has been above the average
range value of the average of the latest
ten subgroups 7 times consecutively.
E393 7below r cm Trend deviation alarm, the subgroup CM
range value has been below the average
range value of the average of the latest
ten subgroups 7 times consecutively.
E394 2sigma x cm Trend deviation alarm, the last subgroup
CM average is outside XCM-bar-bar-2
sigma.
E395 2sigma r cm Trend deviation alarm, the last subgroup
CM range average is outside RCM-bar-
bar-2 sigma.
E400-E499: Communication errors
E401 Duplicate device IDs
on IO bus
Yes Two IO devices with the same ID are
present on the I/O bus.
E403 IO device not respon-
ding
Yes The I/O device is not properly connec-
ted or the ID of the device is not the
same as the one confi gured.
E404 Selector is not connec-
ted or not responding
Yes The selector is not properly connected
or the ID of the selector is not the
same as the one confi gured.