Parameter Description Default value
Rundown torque limits Sets Rundown torque limits to On
or Off.
Off: No limits are set.
On: Torque limits and angle inter-
val are set.
Off
Offset Angle offset before the Angle in-
terval begins.
Length Angle defining the Rundown
torque limit section.
360°
Torque min Torque value for lower Rundown
torque limit.
Torque min Torque value for lower Rundown
torque limit.
{ , : noprofile in element [entry]}
{ , : noprofile in element [p]}0
Nm
Torque max Torque value for upper Rundown
torque limit.
Torque max Torque value for upper Rundown
torque limit.
{ , : noprofile in element [entry]}
{ , : noprofile in element [p]}
19% of Target Tq
Rundown angle limits
By monitoring the angle of rotation during rundown, errors such as missing
washers or bolts with incorrect thread size or length can be detected. For exam-
ple, threads that are too long would require a greater turning angle for the bolt
to reach snug.