Parameter Description Default value
Rundown angle limits Activates Rundown angle limits.
The angle limits are set relative to
when the tool trigger is pressed or
when a specified torque value is
reached. Angle limits will not be
checked during Selftap if Selftap is
activated.
Off: No limits are set.
From trigger: Limit values are set
relative to when the tool trigger is
pressed.
From torque: Limit values are set
relative to when the specified
torque value is reached.
Off
<From torque> Torque value from where Run-
down angle limits are set.
<From torque> Torque value from where Run-
down angle limits are set.
{ , : noprofile in element [entry]}
{ , : noprofile in element [p]}
10% of Target Torque
Angle min Angle value for lower angle limit
from starting point.
100°
Angle max Angle value for upper angle limit
from starting point.
1000°
From trigger
The system starts to monitor the tightening angle as soon as the tool trigger is
pressed and reports if angle limits are violated.
From torque
The system starts to monitor the tightening angle from the specified torque
value and reports if angle limits are violated.