33
Target angle limits
With Target angle limits set, it is possible to monitor whether the nut is turned
the desired angle during the tightening.
Parameter Description Default value
Angle limits Choose the section of the tighten-
ing, in degrees, in which to moni-
tor the angle.
Off: No limits are checked.
From Rundown complete: The
monitoring window is set from
when the Rundown complete
torque is reached.
From torque: The monitoring
window is set from when the speci-
fied torque value is reached.
Torque must be greater than First
torque.
From First target: The monitor-
ing is set from when First target is
reached. This option is not avail-
able if TurboTight is chosen.
Off
<From torque> Torque value from where angle
limits are set.
<From torque> Torque value from where angle
limits are set.
{ , : noprofile in element [entry]}
{ , : noprofile in element [p]}
75% of Target Tq
Angle min Angle value for lower angle limit 90°
Angle max Angle value for upper angle limit 720°
From rundown complete
{ , : profile5 in element [subsection]}