EN Power Focus 600
32
© Atlas Copco Industrial Technique AB - 9836 4954 01
Parameter Description Default value
Target speed Target speed for the Rotate strat-
egy.
<Target speed> Manual tool speed during the Ro-
tate strategy.
{ , : noprofile in element [entry]}
{ , : noprofile in element [p]}
16.5% of Tool max speed
Target angle Angle to turn the spindle. 360°
Target torque limits
By setting the Target torque limits, it is possible to discard a tightening should
the torque result not fall within the specified torque limits. A torque set too high
can cause the bolt to deform as a result of passing the yield point, and can even
break, or can cause the stripping of threads. Not enough torque result in the
clamping force not being enough to withstand the forces for which the joint is
designed.
Parameter Description Default value
Torque limits The tightening is considered as
NOK if the torque result is outside
the range defined by Torque min
and Torque max.
Auto: Torque limits are automati-
cally set to the default values spec-
ified for Torque min and Torque
max.
Manual: Enables the Torque limit
values to be set manually.
Auto
Torque min Torque value for lower torque
limit.
95% of Target torque
Torque max Torque value for upper torque
limit.
120% of Target torque