45
Output signal Description
Generic I/O 7
Generic I/O 8
Generic I/O 9
Generic I/O 10
Automatic mode
Manual mode
Line control done
Line control running Indicates Line control start set in the Power Focus.
Line control alert 1
Line control alert 2
Parameter descriptions
{ , : profile4 in element [iosection]}
Event codes
{ , : profile4 in element [iosection]}
Event
Description Procedure Ack.Code Type Name
1000 Info Controller
started
1010 Info Tool connected
1011 Info Tool discon-
nected
2010 Error Tool software
version mis-
match
Service tool -
update tool soft-
ware
x
2011 Warning ST Accessory
not supported
Contact service x
2012 Warning Communication
error with tool
Re-locate an-
tenna placement.
2013 Warning Illegal ring posi-
tion
If occuring fre-
quently, service
tool
2014 Warning Tool overheated
2020 Warning No motor tuning
– Do motortune
Do motortuning
2021 Warning Motor tuning
failed
Complete motor
tuning else ser-
vice tool.
2022 Info Motor tuning
done