Power Focus 600 EN
© Atlas Copco Industrial Technique AB - 9836 4954 01
47
Event
Description Procedure Ack.
Code Type Name
2072 Info Unknown tool
device con-
nected
2073 Warning Tool trigger su-
pervision failure
HW channel
failure. Miss-
match between
hardware and
software super-
vision of tool
trigger.
2074 Warning Tool indicator
board failure
Tool indicator
board failure.
Service tool
2075 Warning Tool fan voltage
failure
Tool fan voltage
failure.
Service tool
2076 Warning Tool accessory
bus voltage fail-
ure
Tool accessory
bus voltage fail-
ure.
Service tool
2077 Warning Tool trigger sen-
sor error
Tool trigger sen-
sor error.
Service tool
3000 Error Internal soft-
ware error
Contact service x
3010 Warning Controller over-
heated
Event can be
produced by
lowering the
level of
SvHeatsinkTem-
pLimit.
Cool down
3020 Warning System hard-
ware failure
Event can be
produced by
lowering the
level of sVUDc-
VoltageHiLimit.
3021 Warning System voltage
problem
Udc too low or
too high.
3030 Error Factory port, IP
collision
The set IP ad-
dress for the
Factory port, on
the IT-side, is in
use by other de-
vice on the fac-
tory net.
Change IP of
conflicting de-
vice or con-
troller which de-
tected the IP
collision.
3031 Info Factory carrier
lost
The factory
port's carrier has
been lost (cable
disconnected).
Connect the ca-
ble again.