© Atlas Copco Industrial Technique AB - 9836 6528 01
The POWER FOCUS 6000 has a function for sensing the line voltage automatically. This means that the
POWER FOCUS 6000 automatically switches to the voltage you connect to it.
Mains Fuse
Recommended mains fuses (power outlet):
Tool Mains voltage [V] Fuse [A]
SR21/STR61 115 15
230 16
ST31/ST61/ST81/ST101 115 15
230 16
If you are running the POWER FOCUS 6000 as a stand-alone unit and trigger the tools manually (at ran-
dom) it is normally possible to connect up to three POWER FOCUS 6000 units to one power drop. If you
are synchronizing the spindles you need one drop for each POWER FOCUS 6000 unit. The fusing in the
power drop must be of the time delay type.
Power Consumption
Power consumption depends on the speed and torque of the tool. High speed and torque increase power
consumption.
Tool Off mode [W] Idle mode [W] Active mode [W]
SR21 <0.5 <26 1100
STR61 <0.5 <26 1200
ST31 <0.5 <26 1050
ST61 <0.5 <26 1200
ST81 <0.5 <26 1300
ST101 <0.5 <26 1500
The power consumption in idle mode has been measured without any controller accessories or tool
accessories connected.
Network Connections
Factory LAN - 100/100 Mb/s
Service LAN - 100/100 Mb/s
Service Overview
Service Recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
Replace any defective or worn parts

Other manuals for Atlas Copco POWER FOCUS 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco POWER FOCUS 6000 and is the answer not in the manual?

Atlas Copco POWER FOCUS 6000 Specifications

General IconGeneral
ModelPOWER FOCUS 6000
CategoryController
ConnectivityEthernet, USB
Supply voltage100-240 V AC
Frequency50/60 Hz
Fieldbus protocolsPROFINET, EtherNet/IP
Data storageInternal memory
Operating temperature0°C to +45°C
Storage temperature-20 to 70 °C
Relative humidity90% (non-condensing)