5.2 Operating
5.2.1 Starting
Move the control panel power switch to ON. The
display of the User Interface will light up. See also
chapter 5.3.
Use the arrow keys to set the working pressure.
Push the start button on the panel. The horn will
sound.
The compressor can be loaded after the warmup
period.
Manual: push the button below the indication
LOAD, in the display.
Automatic: the compressor will load
automatically when the button below the
indication AUTO LOAD, in the display, is
pushed during the warmup period.
The unit will LOAD/UNLOAD according to the
air demand.
Open the air outlet valve(s).
When the unit is in the standby status for a long time,
the following action should be performed:
Without application: turn OFF the battery switch.
Running: supply power to the battery conditioner.
5.2.2 During operation
Regularly carry out following checks:
Check alarm lamp at the front and alarm lamp and
horn at the back of the unit.
When starting up the unit and also when a
shutdown occurs, the alarm lamps and the horn
will be activated. But when a warning occurs, only
the lamps will be activated.
Check the air filter service indicator.
If the yellow signal shows in the window of the
indicator (see section 6.4.2.3), clean or replace the
filter elements.
Check the air outlet temperature of the MP
compressor element.
5.2.3 Stopping
Close the air outlet valve(s).
On the User Interface, push the function button
below the indication Noload.
Push the Stop button.
Once the engine has stopped, switch the control
panel power switch to the OFF position.
Turn OFF the battery switch
Make sure that nobody is in the unit
and all doors are closed prior to
starting the unit.
The start/stop instructions are
available in different languages on
request.
!
The pressure is not immediately
relieved from the unit, when the
Stop button is pushed.
!

Table of Contents