- 42 -
5.4.5 Cranking status
The starter motor output is activated when the CCM
enters this status.
The Crank counter is reset to 0.
Other actions and signals have no effect in this status.
5.4.6 Warmup status
5.4.6.1 Manual start
S Warnings R Are shown on the screen
A Shutdowns R To start failure status (see
section 5.4.11)
A Crank counter = Max.
crank attempts
R To start failure status (see
section 5.4.11)
A Starter lockout activation
RPM reached
R The starter motor output
is activated; to Warmup
status (see section 5.4.6)
A Emergency stop button R To emergency stop status
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pressure + 0.1 bar/
second
A Power OFF switch R To stopping status (see
section 5.4.10)
A Stop command To stopping status (see
section 5.4.10)
If cranking:
S Crank time elapsed S The starter motor output
is desactivated for the
duration of the crank
time (resting).
Crank counter +1
If resting:
S Crank time elapsed S The starter motor is
reactivated, the screen
shows “Crank attempt
X”, with X being the
Crank counter.
S Warnings R Are shown on the screen
A Shutdowns R To start failure status (see
section 5.4.11)
A Max. warmup time
elapsed
R Not Loaded status or
Load/Unload status (see
section 5.4.7)
A Emergency stop button R To emergency stop status
(see section 5.4.13)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pressure + 0.1 bar/
second
A Stop command R To stopping status (see
section 5.4.10)
A Power OFF switch R To stopping status (see
section 5.4.10)