- 49 -
The parameters the operator can change are:
– Display Luminosity
– Pressure Units (Metric/Imperial)
– Temperature Units (Metric/Imperial)
– Flow Units (Metric/Imperial)
– Start method (if Autostart = enable or disable)
– Autostart pressure (if Autostart = enable or enable
lock)
– Stop method (if Autostop = enable or disable)
– Autostop time (if Autostop = enable or enable
lock)
– Control mode (if Remote = enable or disable)
(Local/Remote)
– Air discharge temperature control (if Air
Discharge Temperature Control Parameter =
enable or disable)
– Air discharge temperature setpoint (if Air
Discharge Temperature Control Parameter =
enable or enable lock)
– Reload/Unload pressure (if enabled)
Other actions and signals have no effect in this status.
5.4.16 Process Info status
5.4.16.1Two key access
Depending on the setting of the Infobutton parameter,
the operator has access to the Process Info status by
pressing a single named function key, the Process
Info button. In that case the Infobutton parameter is
enable.
When the Infobutton parameter is disable, the access
to the Process Info status is made by a two button
function.
While pressing the unnamed function button, which
otherwise would
be the Process Info button, the other
function button has to be pressed.
The Infobutton parameter can be changed with the
PC, Rental companies clearance.
5.4.16.2Process Info status function
This status is not an active status, but can be entered
from the following statuses:
– Standby status
– Permissive Start status
– Cranking status
– Warmup status
– Noload status
– Load/Unload status
– Cooldown status
– Shutdown status
– Start Failure status
– Emergency Stop status
The Process Info status gives a summary of all
parameters measured by the CCM, and those taken
from the ECM’s dataline.