- 45 -
5.4.8.2 Automatic stop
Other actions and signals have no effect in this status.
5.4.9 Cooldown status
Other actions and signals have no effect in this status.
S Warnings R Are shown on the screen
A Shutdowns R To Shutdown status (see
section 5.4.12)
A Emergency stop button R To emergency stop status
(see section 5.4.13)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pressure + 0.1 bar/
second
A Stop command R To Cooldown status (see
section 5.4.9)
A Power OFF switch R To Cooldown status (see
section 5.4.9)
A Noload command R To Not Loaded status
(see section 5.4.7)
If Loaded:
S Unload pressure reached R “Unload” appears on the
screen
Autostop timer activated
If Unloaded:
A Reload pressure reached R “Load” appears on the
screen
Autostop timer reset
S Autostop time elapsed R To stopping status (see
section 5.4.10)
S Warnings R Are shown on the screen
A Shutdowns R To shutdown status (see
section 5.4.12)
A Cooldown time elapsed R Stopping status (see
section 5.4.10)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pressure + 0.1 bar/
second
A Emergency Stop button R To emergency Stop
status (see section 5.4.13)