- 43 -
Other actions and signals have no effect in this status.
5.4.6.2 Automatic start
Other actions and signals have no effect in this status.
A Auto load button
or Remote Load input
if Remote control mode
R After the Warmup status,
the CCM will skip the
Not Loaded status and go
directly to the Load/
Unload status (see
section 5.4.8)
“Automatic load” will
appear on the screen
If min. Warmup time is elapsed:
S Coolant = Warmup
temperature
R To Not Loaded status
(see section 5.4.7)
or Load/Unload status
(see section 5.4.8)
If Auto Load button was pressed:
A Manual load button
or Remote Load input
if Remote control mode
R Auto Load condition is
canceled
S Warnings R Are shown on the screen
A Shutdowns R To shutdown status (see
section 5.4.12)
A Max. warmup time
elapsed
R To Not Loaded status
(see section 5.4.7) or
Load/Unload status (see
section 5.4.8)
A Emergency stop button R To emergency stop status
(see section 5.4.13)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pressure + 0.1 bar/
second
A Stop command R To stopping status (see
section 5.4.10)
A Power OFF switch R To stopping status (see
section 5.4.10)
A Manual load button
or Remote Load input
if Remote control mode
R After the Warmup status,
the CCM will go to the
Not Loaded status (see
section 5.4.7) before
going to the Load/
Unload status (see
section 5.4.8)
“Automatic load” will
disappear from the
display
If min. Warmup time is elapsed:
S Coolant = Warmup temp. R To Load/Unload status
(see section 5.4.8)
or Not Loaded status (see
section 5.4.7)
If Manual Load button was pressed:
A Auto load button
or Remote Load input
if Remote control mode
R Manual Load condition
is canceled