Inspect/Adjust fan/alternator belt x x x x
Replace fan/alternator belt x
Measure alternator insulation resistance (11) xx
Test Earth Leakage Relay (12) x x x
Check emergency stop (12) x x x
Clean radiator (1) xx x
Clean intercooler (1) xx x
Check for obstructions on crankcase breather system /
filter and hoses
x
Drain condensate and water from spillage-free frame
or catch basin (8)
xx x
Check for leaks in engine-, air-, oil-, or fuel system x x x
Hoses and clamps - Inspect/Replace x x x
Check electrical system cables for wear xx
Check/Test glow plugs - grid heater xx
Check torque on critical bolt connections xx
Check electrolyte level and terminals of battery (10) x x x
Analyse coolant (4) (7) xx x
Check external fuel connection (option) xx
Grease locks and hinges xx x
Check rubber flexibles (9) xx
Drain/Clean fuel tank water and sediments (1) (13) x x x
Replace fueltank breather filter x
Drain lube oil/condensation from intercooler x
Maintenance schedule Daily
50 hrs
after initial
start-up
Every 500
hours
Every 1000
hours
Every 2000
hours
Yearly
Service pak - - 2912 4505 04 2912 4506 05 2912 4507 06 -