44
from the starting power to the peak power);
3)Laser power
Set the power of the laser.
4) Power ramp down
Set the power slow-down delay (the time it takes for the output power to
drop from the peak power to the cut-off power).
Note: Only the system with optional wireless control module has the power
slow down function!
5) Power start:
Show the power when the light starts.
6) Power off:
Show the power when the light is stopped.
7) WireMoment:
If the control system is equipped with a stepping wire feeder, the torque
of the stepping wire feeder can be adjusted according to the load of the stepping
wire feeder.
8) Stop delay:
After setting the light-off delay time, the light will not be turned off
immediately after releasing the off switch of the welding head, but the light
will really stop after the light-off delay period. Use the time of the light-
off delay to realize that the welding wire is separated from the workpiece after
the light is stopped.
Note: The light-off delay time is up to 500ms. When the light-off delay
time is set too long, please confirm that the light has been stopped before
placing the welding head to prevent laser damage.
9) Pulse-Time:
Set the light emission time in burst mode, the maximum burst time is 1000ms.
10) Blow switch