Alarm Err-S001: Wire
feeder communication
failure!
Check the communication
line between the controller and
the stepping wire feeder, and
plug the communication interface
again after power off.
This alarm
is only for the
optional
stepping wire
feeder.
AlertErr-S002:
Stepping wire feeder driver
alarm
Check the line connection
between the motor and the drive,
check whether the power supply
voltage is at 24V.
This alarm
is only for the
optional
stepping wire
feeder.
Alarm Err-S003: Motor
shaft lock failure!
After the power is off,
check the line connection
between the motor interface of
the stepping wire feeder and the
motor driver, and re-plug and
unplug the motor terminal of the
driver.
This alarm
is only for the
optional
stepping wire
feeder.
Alarm Err-C001:
Chiller alarm!
Check whether the water
cooler works normally
Alarm Err-All: There
are many faults at present,
please check detailed fault
information!
There are many current
faults, please troubleshoot them
one by one.
There is no alarm
when the equipment is
running normally!
The current device is
operating normally.