45
Open/close solenoid valve
11) Off centering
Adjust the lateral offset of the optical core
12) Wire retract when light off:
After the light emission stops, the welding wire will automatically return
to a certain length to facilitate the next welding. The length of the retracted
welding wire is determined by the set parameters.
13) Wire feeding delay after light off
After the light-off and wire-returning action is completed, and after this
delay period, the wire feeder will feed wire again.
14) Wire feeding after light-off wire feeding delay
After the light-off wire feeding delay is over, the length of wire output
from the wire feeder is determined by this parameter to facilitate wire breakage.
15) Wire feeding speed after light off
After the light emitting is completed, the light-off wire returning and
feeding speed.
16) Automatic wire breaking
After turning it on, there will be a wire breaking action at the end of
each wire feeding and light emission. After turning it off, there will be no
wire breaking action at the end of each wire feeding and light emission.
3、Equipment alarm and handling
3.1 Equipment alarm
If the alarm is not cleared, the red indicator light will flash. The red