Fast Track Guide 7. Upgrading the Mediant 1000
Version 5.0 35 October 2006
Figure 7-6: 'Auxiliary Files' Screen (e.g., SIP Gateways)
¾ To save the loaded auxiliary files (e.g., CPT) to flash memory and reset
the gateway, take these 3 steps:
1. On the main menu bar, click the Maintenance button; the 'Maintenance Actions' screen is
displayed.
2. Saving an auxiliary file to flash memory may disrupt traffic. Therefore, disable all traffic on
the device by performing a Graceful Lock:
a. Under the 'LOCK / UNLOCK' group, select 'Yes' from the 'Graceful Option' drop-down
list.
b. In the 'Lock Timeout' field, enter the time (in seconds) after which the gateway locks.
c. Click LOCK; now new calls are accepted and the gateway locks and terminates all calls
after the 'Lock Timeout' value expires. Note that if no traffic exists and the time has not
yet expired, the gateway locks.
3. Under the 'RESET' group, select the 'Yes' option from the 'Burn to FLASH' drop-down list,
and then click
Reset; the auxiliary files are saved onto flash and the Mediant 1000 restarts.

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals