3.4.1  Power Surge Protection and Grounding 
This section discusses power surge protection and grounding of MP-124. 
 
 
Warning:  
•  Ensure that you connect MP-124 to an electrical socket outlet that 
provides protective earthing (grounding). Prior to connecting power, refer 
to the Regulatory Information provided in the User’s Manual. 
 
For Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun 
pistorasiaan." 
For Norway: "Apparatet rna tilkoples jordet stikkontakt." 
For Sweden: "Apparaten skall anslutas till jordat uttag." 
•  MP-124 is immune against power surge levels of up to 1 Kilovolts (KV) as 
required by the following standards: IEC 61000-4-5, EN 55024, and EN 
300386. 
•  For installations where wires are routed outside the building, the 
Telecommunication site must comply with ETS 300-253 “Earthing and 
Bonding of Telecommunication Equipment in Telecommunication 
Centers”. 
•  Power surges above protection levels as required by EN 55024/EN 
300386 may cause damage to MP-124. 
•  MP-124 provides only Secondary Protection against power surges. In 
deployments where the telephone lines are installed outside, you must 
install Primary Protection against lightning. Only lightning protectors 
recommended by AudioCodes must be used - specifically, manufactured 
by Circa. Failing to install Circa primary surge protectors, failing to 
comply with the grounding instructions or any other installation 
instructions, may cause permanent damage to MP-124.  
•  As most of the installation is the responsibility of the customer, 
AudioCodes can assume responsibility for damage only if the customer 
can establish that MP-124 does not comply to the standards specified 
above (and MP-124 is within the hardware warranty period). 
 
 
Note:  Proper grounding is crucial to ensure the effectiveness of the primary 
protector and MP-124 must be connected to the equipotential ground bus (in 
electrical switch board) that is connected directly to the grounding of the 
foundation reinforcement conductor.  
 Before installation, loop-testing grounding measurements must be done by a 
certified electrician to verify the quality of the grounding connection. The 
grounding impedance must not exceed 0.5 ohm. 
 
Lightning is the transient passage of electrical current between a cloud and the surface of 
the earth. Part of the lightning current can be carried inside a building from electrical lines 
and analog and/or digital telephone lines located outside. This direct injection of lightning 
current inside a building can cause significant damage to electronic circuits and equipment. 
To protect MP-124 from these power surges, MP-124 must be connected to an external 
lightning protector. You must use a  lightning  protector of the type CIRCA  4B3S-75 
manufactured by CircaTelecom (http://www.circatelecom.com). The connection must be 
made using the terminal fixture of the type CIRCA 2625QC/QC or 26100QC/QC.