Installation Manual 30 Document #: LTRT-59811
MediaPack Series
2.2.4.3 Connecting MP-124 to FXS Interface
The MP-124 interfaces with the analog telephone interfaces by connecting to a main
distribution frame (MDF), using a 50-pin Telco cable.
MP-124 Safety Notice
To protect against electrical shock and fire, use a 26 AWG min wire to connect
analog FXS lines to the 50-pin Telco connector.
Warning: To reduce noise interference, use a twisted pair Octopus cable that is
terminated on a metal-hooded 50-pin Telco connector.
¾ To connect MP-124 to the FXS telephone interface:
1. Wire the 50-pin Telco connectors according to the pinouts in the table below:
Table 2-7: Pin Allocations of the 50-pin Telco Connector
Phone Channel Connector Pins Phone Channel Connector Pins
1
1/26
13
13/38
2
2/27
14
14/39
3
3/28
15
15/40
4
4/29
16
16/41
5
5/30
17
17/42
6
6/31
18
18/43
7
7/32
19
19/44
8
8/33
20
20/45
9
9/34
21
21/46
10
10/35
22
22/47
11
11/36
23
23/48
12
12/37
24
24/49
Figure 2-20: 50-pin Telco Connector (MP-124/FXS only)
2. Attach each pair of wires from a 25-pair Octopus cable (not supplied) to its
corresponding socket on the MDF adaptor block’s rear panel.
3. Connect the wire-pairs at the other end of the cable to a male 50-pin Telco connector
(not supplied).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack and is the answer not in the manual?

AudioCodes MediaPack Specifications

General IconGeneral
Fax SupportT.38, G.711 pass-through
Humidity10% to 90% non-condensing
ModelMediaPack
CategoryGateway
Voice Channels2, 4, 8, 24 (depending on the specific model)
Network InterfacesEthernet (10/100/1000 Mbps)
ProtocolsSIP, MGCP
Voice CodecsG.711, G.726, G.729, iLBC
ManagementWeb-based, SNMP, CLI
SecurityTLS, SRTP, HTTPS, SSH
FXS PortsVaries by model (e.g., 8, 16, 24)
FXO PortsVaries by model (e.g., 8, 16, 24)
Ethernet Interfaces10/100/1000 Mbps
Power SupplyAC 100-240V, 50-60Hz or DC (varies by model)
DimensionsVaries by model (e.g., 1U, 2U rack mount)
WeightVaries by model
Operating Temperature0°C to 45°C (32° to 113°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)