Type of actuation | Electric |
---|---|
Handwheel | Optional |
Frequency | 50 Hz / 60 Hz |
Power supply | AC |
Torque range | 10 Nm to 100 Nm |
Voltage | 230/400 V |
Communication | Modbus, Profibus |
Motor | Three-phase AC motor |
All personnel must be well-versed with safety and warning instructions in this manual.
Failure to observe warnings and notes may lead to serious injuries or damage.
Assembly, connection, commissioning, operation, and maintenance must be carried out by qualified personnel.
Prior to commissioning, it is important to check settings meet application requirements.
Transport to place of installation in sturdy packing, avoid exposure to atmosphere and protect against rains.
Store in well-ventilated, dry room, protect against dampness and dust.
Products are protected by special packaging for transport, using environmentally friendly materials.
LCD screen provides status, operation, and parameter setting details.
Features/options can be configured using software via selector switches and rotating knob.
Actuators support various interfaces like Remote, 4-20mA, Bluetooth & MODBUS-RTU.
ESD feature can be configured to run in Close direction or OPEN/CLOSE/STAY.
Actuators store events like faults, statuses, and number of starts using a Bluetooth module.
Inhibit is an interlock for open/close operations, can be enabled or disabled in software.
Allows controlling the actuator in remote 4-wire mode even when in 4-20mA or MODBUS mode.
Actuator stops in Remote Mode when rotary knob is rotated on the Actuator Front Panel.
Used to control valve movement, opening or closing slowly towards the end position.
Used to obtain time-stamp for event logging, powered by a Super Capacitor.
Power Supply Card features include Under/Over Voltage Protection and Short Circuit Protection.
Details on different output drive types (A, B, C, D, E) and their mounting procedures.
Two rotary selector switch configurations available with 3 modes and 2 states.
Graphical LCD for new actuator series with scroll-in and Enter features.
Flowchart showing navigation through main screens like Valve Position, Torque, Faults, Warnings.
Entering PROGRAM MODE allows setting features like General settings, Remote settings, and Relay settings.
Steps to enter Diagnostic Mode: keep selector switch in OFF, press STOP for 3 seconds.
Steps to enter Calibration Mode: select OFF, press STOP, enter password, select Device Calibration.
Procedure to calibrate the limit open setting, showing current value and steps to set/store.
Tips for setting limit switches and additional tips to avoid issues during operation and maintenance.
Preset torque can be done by referring the 'Device calibration' flow chart.
Description of customer end connections based on terminal numbers.
Description of components within Auma India controls: CPU CARD, PS CARD, Profibus, SIL, Adaptor.
Description of components related to the Norm Actuator: motor, encoder, limit switch.
Description of customer end connections and command signals for actuators.
Description of potential free contacts for relay feedback to customer's DCS.
Details on programmable relays for status feedback to customer's DCS.