12-EN
The measurement is carried out between PT_SENSE and PT_RTN,therefore the element to be measured must be wired
betweenthesetwosignals.
The PT100/PT1000 sensor is automatically recognised by the system and is therefore acquired without the need for
furthersettings.
Regarding the connection of the sensorswith outputrange 0...10Vdc,these must bepowered and the power supply can
be taken directly from the system power supply; the grounding of the power supply and the grounding of the signal
readingisthesame.
For the sensor connection,beside the power supply, it is necessary to connect the signal proportionally to the quantity
measuredatoneofthetwoanaloginputsavailable(Aln1/Aln2).
Thegroundingofthe signaltobe measured(ifdifferentfromthe groundingofthe powersupply within thePower-One
sensorrangeonlyinthewindspeedsensorPVI-AEC-WIND-COMPACT)mustbeconnectedtotheAln_RTNclamp.
After carrying out the connections it is necessary to configure the sensor in the system so that the correct quantity is
acquired:
1. Enterthemainmenuasadministrator(Seepar.'C’).
2. Accessthemenu .
3. Select the item and then select the sensor model connected to the AIn1 input of the system (the
selectedmodelwillbeidentifiedwithanasterisk(*)).
4. Select the item and then select the sensor model connected to the AIn2 input of the system (the
selectedmodelwillbeidentifiedwithanasterisk(*)).
'SETTINGS'>'IOSETTINGS'
ANALOG INPUT1”
ANALOG INPUT2”
PVI-AEC-EVO ......
12.00.00 01/01/11
>io settings
UPGRADE FIRMWARE
menu pin
0***
>ANALOG INPUT1
ANALOG INPUT2
>settings
change password
ENTER ENTER
ENTER
ENTER
ENTER
ENTER
>ANALOG INPUT1
T1000-INTEGR *
CHANGE VALUE
NEXT
DIGIT
SET PIN TO 0010
CHANGE
SENSORS
>ANALOG INPUT2
PULSE IN1
ENTER
ENTER
>ANALOG INPUT2
RAD-13TC *
CHANGE
SENSORS
Note: Incaseofconnecting PT100/1000sensors withonlytwoterminals,connectaterminaltothePT_SENSE
clampandaterminaltothePT_RTNclamp,thenmakeajumperbetweenPT_ALIMandPT_SENSE.
ystem automatically
the inverters can be
ring the scanwill be
edbyscrollingusing
'CURRENTVALUES'>
or.
NEXT
DIGIT
0010
ENTER
on the number of
tonly oneanalog
t.
readingthrough the
Monitoring System
EN - ENGLISH