Operating manual Ruby EN 5 | Technical data
15
Particular precautions for assembly, installation or maintenance
Described in the individual sections of the operating manual.
Fuel Preferred
fuel
(only one)
2
:
Other suit-
able fuel(s)
3
:
ηs
[x%]:
Space heating emis-
sions at nominal heat ef-
ficiency (*)
Space heating emis-
sions at minimum
heat efficiency
4
(*) (**)
PM OGC CO NOx PM OGC CO NOx
[x] mg/Nm³ (13% O2)
5
[x] mg/Nm³ (13%
O2)
6
Log, moisture content ≤
25 %
no no - - - - - - - - -
Compregnated laminated
wood,
moisture content < 12 %
yes no 87.6 19 1 11 123 10 4 178 105
Other woody biomass no no - - - - - - - - -
Non-woody biomass no no - - - - - - - - -
Anthracite and dry steam
coal
no no - - - - - - - - -
Coking coal no no - - - - - - - - -
Semi-coke no no - - - - - - - - -
Bituminous coal no no - - - - - - - - -
Lignite briquettes no no - - - - - - - - -
Peat briquettes no no - - - - - - - - -
Briquettes made from a
mixture of fossil fuels
no no - - - - - - - - -
Other fossil fuels no no - - - - - - - - -
Briquettes made from a
mixture of biomass and
fossil fuels
no no - - - - - - - - -
Other mixture of biomass
and solid fuels
no no - - - - - - - - -
(*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide