14
Step 3
1. Place the wirebox against the wall with
an appropriate height and level it using
the built-in spirit level (A).
Recommended height: 850–1150 mm
For ADA Accessibility: 700–800 mm
2. Make three marks at the designated
location. Remove the wirebox
temporarily.
3. Drill three holes at the marked
locations, measuring 8 mm in
diameter and 50 mm in depth.
4. Tap the three wall anchors (A) into the
drilled holes.
5. Attach the wirebox to the wall using
the three Φ5 x 40 self-tapping screws
(B). Use the power drill with a Phillips
bit (PH2) to tighten the screws.