Fault Message Description
305 Bottom Blowdown Controller
Main Power Fault
Main power has failed on bottom blowdown controller
Warning
Contact Autoflame approved local tech centre
350 Bottom Blowdown Servo Not
Commissioned
Bottom blowdown controller has not been requested to drive
servomotor to closed since it was powered on
Warning
Commission bottom blowdown servomotor
400 Draught Pressure Sensor
Timeout
No comms within 2 seconds from draught pressure sensor
Alarm or warning depending on option 88
Check wiring and screen on terminals DT+, DT-, DP- and DP+
410 Draught Pressure Outside
Tolerance
Pressure is outside of set tolerance
Alarm or warning depending on option 88
Check expansion option 87
420 Fuel flow Feedback Input Low 3mA or lower received from 4-20mA external fuel flow input
Warning
Check feedback from external fuel flow input
Check wiring on terminals EX- and EX+
430 Fuel flow Feedback Below
Tolerance
Fuel flow signal below fuel flow feedback fault tolerance
Warning
Check feedback from external fuel flow input
Check option 60
431 Fuel flow Feedback Above
Tolerance
Fuel flow signal above fuel flow feedback fault tolerance
Warning
Check feedback from external fuel flow input
Check option 60
440 Temperature Sensor T1Fault Fault or no comms with T1 sensor
Warning
Check wiring and screen on terminals –and T1
441 Temperature Sensor T2 Fault Fault or no comms with T2 sensor
Warning
Check wiring and screen on terminals – and T2
442 Temperature Sensor T3 Fault Fault or no comms with T3 sensor
Warning
Check wiring and screen on terminals – and T3
443 Make Up Flow Meter Fault Fault or no comms with make up flow meter
Warning
Check wiring and screen on terminals F- and MF
444 Condensate Flow Meter Fault Fault or no comms with condensate flow meter
Warning
Check wiring and screen on terminals F- and CF
445 Deaerator IO Comms Fault Fault or no comms with deaerator IO
Warning
Check wiring and screen on terminals 6T+ and 6T-