34 © 2001 Directed Electronics, Inc. Vista, CA
Door input does not respond with the progressive trigger, but with immediate full alarm:
Which zone does the LED indicate? If the LED indicates that the impact sensor caused the trigger, the sensor may
be detecting the door opening. Reducing the sensitivity or relocating the sensor can often solve this problem.
(See Table of Zones section of this guide.)
The Valet
®
switch does not work:
Is it plugged into the correct socket? (See Plug-In Harnesses section of this guide.)
Check the System Features Learn Routine for the programmed Valet
®
pulse count. (See the System Features Learn
Routine section of this guide.)
The security system will not override with the Valet switch:
When overriding the security system, be sure to wait 3 seconds after the Valet switch has been pressed (1-5
pulses, depending on how your system was programmed.) (See the System Features Learn Routine section of this
guide for programming the Valet pulse count.)
Status LED does not work:
Make sure that it is plugged in. (See Plug-In Harnesses section of this guide.) Is the LED plugged into the correct
socket?
Cannot access the Transmitter/Receiver Learn Routine through the Valet switch:
Is the Valet switch plugged into the correct socket? (See Plug-In Harnesses section of this guide.)
The system may be programmed for Transmitter Lockout. This feature can only be toggled on or off by using a
DEI Bitwriter or PC interface module (DEI part number 996T).
Cannot access the System Features Learn Routine through the Valet switch:
Is the Valet switch plugged into the correct socket? (See Plug-In Harnesses section of this guide.)
Are the door inputs connected?
Is the YELLOW H1/9 wire connected to the primary ignition wire of the vehicle?
The system may be programmed for Feature Lockout, which can only be toggled on or off by using a DEI Bitwriter
or PC interface module (DEI part number 996T).