4. Install the S/T Interface Linecards (SILCs) and/or U Interface Linecards (UILCs) or
Basic Rate Signaling Concentrators (BRSCs).
5. Connect ISDN BRI terminals. This procedure comprises the following:
Connect the system to the Main Distribution Frame (MDF).
Cross-connect the MDF.
Connect ISDN BRI terminals to the DSL.
Initialize the ISDN BRI terminals.
Selecting the card slots
To install ISDN BRI cards, perform the following steps:
1. Identify all the slots that can contain the ISDN BRI cards. First identify the modules
with unused network and peripheral card slots and then remove the covers from the
identified modules. To identify the modules, use the following Print Programs.
LD 22 to print the system configuration and identify unused network card slots
to install MISPs
LD 22 REQ: prt TYPE: cfn
LD 20 to list unused IPE card slots to install SILCs, UILCs and BRSCs
LD 20 REQ: prt TYPE: luc TN: l s
Table 1: ISDN BRI card location on page 16 lists the modules that can house ISDN
BRI cards.
Table 1: ISDN BRI card location
Modules
Supported
Systems
SILCs, UILCs,
BRSCs
MISPs
NT4N41 Core/Network Module Large
Systems
Network slots
0-7
NT8D35 Network Module 81C CPPII Network slots
5-12
NT8D37 IPE Module All systems IPE slots 0-15
11c cabinet slot 1–9 slot 1–9
NT414 chassis slot 1–4 slot 1–4
MG1010 slot 1–10 slot 1–10
2. Locate the card slots in the modules that house ISDN BRI cards. Group all SILCs,
UILCs, BRSCs, superloops and the MISP that supports them in the same network
group to avoid using junctors for dedicated connections.
3. For the Communication Server 1000E, make sure the MISP is in the same IPMG
as the BRI cards.
Installing ISDN BRI hardware
16 ISDN Basic Rate Interface Installation and Commissioning March 2011