Specification Value
Operating (for altitude less
than 950m or 3,117ft)
10° to 35 °C (50° to 95 °F) with no direct sunlight on the equipment.
Storage -40° to 65° C (-40° to 149° F) with a maximum temperature gradation of
20 °C (36 °F) per hour
Relative humidity
Operating 10% to 80% (non-condensing) with 26 °C (78.8 °F) maximum dew point
Non-operating 5% to 95% with 33°C (91 °F) maximum dew point
Related links
Physically connecting the new server on page 26
Installing the server in the rack
About this task
Note:
Although not used frequently, Avaya customers are required to have a monitor, USB keyboard,
and USB mouse available for use by installation and/or servicing technicians.
Before you begin
Get the Rack Installation Instructions that are shipped with the hardware for more information. If not
shipped with the hardware, see the Dell documentation Web site for instructions.
Procedure
1. Examine contents of shipping container (Avaya provided equipment), and ensure that the 6-
digit material code on the order matches the 6-digit material code on the shipping container.
2. Verify that the rack is installed according to the manufacturer's instructions and in
accordance with all local codes and laws. Verify that the rack is grounded in accordance with
local electrical code.
3. Remove the cabinet doors, if necessary.
4. Attach the rails to the rack
The rails included with the server will accommodate most square-hole racks. If these rails do
not fit the rack, the customer must provide rails or a shelf for rack installation. Also, the rails
included with the server might not work with round-hole racks. The customer can obtain rails
and/or a shelf from any distributor, for example
http://www.racksolutions.com/. The customer-
provided rails and rack must be on site prior to the first day of installation.
Note:
The customer is responsible for any rack screws.
5. Attach the server to the rack.
6. Connect the power cord(s).
Installing the new streaming and recording server
August 2017 Installing the Avaya Equinox Streaming and Recording Server 34
Comments on this document? infodev@avaya.com