Parameter name Default
value
Description
• 1: Call recording tone is not
generated.
RECORDINGTONE_INTERVAL 15 Specifies the number of seconds
between call recording tones.
Valid values are 1 through 60.
RECORDINGTONE_VOLUME 0 Specifies the volume of the call
recording tone in 5dB steps.
Value Operation:
• 0: The tone volume is equal to the
transmit audio level (default).
• 1: The tone volume is 45dB below
the transmit audio level.
• 2: The tone volume is 40dB below
the transmit audio level.
• 3: The tone volume is 35dB below
the transmit audio level.
• 4: The tone volume is 30dB below
the transmit audio level.
• 5: The tone volume is 25dB below
the transmit audio level.
• 6: The tone volume is 20dB below
the transmit audio level.
• 7: The tone volume is 15dB below
the transmit audio level.
• 8: The tone volume is 10dB below
the transmit audio level.
• 9: The tone volume is 5dB below
the transmit audio level.
• 10: The tone volume is equal to
the transmit audio level.
RECOVERYREGISTERWAIT
60 Specifies a number of seconds. If
no response is received to a
REGISTER request within the
number of seconds specified by
WAIT_FOR_REGISTRATION_TIM
ER, the phone will try again after a
randomly selected delay of 50% to
90% of the value of
RECOVERYREGISTERWAIT.
Table continues…
Appendix
December 2018 Installing and Administering Avaya J100 Series IP Phones 252
Comments on this document? infodev@avaya.com