EasyManua.ls Logo

Avaya S8700 - Page 132

Avaya S8700
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedure
555-233-142
8-828 Issue 1 May 2002
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test analog port maintenance software
and call processing agree on the on-/off-hook status of the Maintenance/Test
analog port.
Table 8-354. Test #270 Clear Error Counters
Error
Code
Tes t
Result Description / Recommendation
PASS The message to clear the Maintenance/Test circuit packs counter for Background
Maintenance Failures has been sent.
Continued on next page
Table 8-355. Test #566 Hook State Inquiry
Error
Code
Tes t
Result Description / Recommendation
1 ABORT Switch hook audit timed out. No response was received from the circuit pack
for information about the switch hook state.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, replace the circuit pack and repeat the test.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
Any FAIL Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to fail reset the circuit pack via the busyout board
UUCSS, reset board UUCSS, release board UUCSS command
sequence.
3. Retry the command at 1-minute intervals up to 3 times.
PASS Call processing and Maintenance/Test analog port maintenance software
agree on the Maintenance/Test analog port hook state.
Continued on next page

Table of Contents

Other manuals for Avaya S8700

Related product manuals