SYSTEM (System)
Issue 1 May 2002
8-1063555-233-142
SYSTEM (System)
The SYSTEM MO is used to log information about system resets, including
interchanges. When software encounters a problem with hardware, or with its
own processes, and requests a restart to clear the problem, an error is logged
under SYSTEM. For example, if there is a loss of clocking in a system with
duplicated servers, the system switches to the other clock and then executes a
level 2 system reset to recover from hardware problems caused by the loss of
clock. Errors logged under SYSTEM can help to determine the cause of a reset.
The display initcauses screen should also contain information about the reset.
See ‘‘Troubleshooting a Duplicated Server’’ in Chapter 4 for more information
about interchanges.
Error Log Entries and Test to Clear Values
MO’s Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. SYSTEM has no associated alarms and thus appears only in the Error Log. There are no tests
that run on SYSTEM.
Full Name of MO
SYSTEM None None System
Table 8-456. System Error Log Entries
Error Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
8 (a) 0 None
9 (b) Any None
10 (c) Any None
601 (d) Any None
602 (e) Any None
605 (f) (p) None
606 (g) Any None
607 (h) Any None
6001 (i) Any None
6002 (j) (o) None
6003 (k) (o) None
6101 (l) Any None
6102 (m) (o) None
6103 (n) (o) None