Maintenance Object Repair Procedure
555-233-142
8-1006 Issue 1 May 2002
REM-OFF (Remote Office)
An instance of this MO (REM-OFF) is associated with every Remote Office box
that is administered on the switch. This MO monitors keep alive and periodic
PING test failures, and if these errors occur, they are logged against this MO.
Error Log Entries and Test to Clear Values
C-LAN Board
Location
The physical location of the circuit pack in CCcss format
(cabinet, carrier, slot)
Number of
Routes Removed
The number of routes that were deleted from the TN799
(C-LAN) route tables
Number of
Routes Added
The number of routes that were added from the TN799
(C-LAN) route tables
MO’s Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1. UU is the universal cabinet number (1–64). C is the carrier designation (A, B, C, or D). SS is the number of the
slot where the circuit pack resides (01–10).
Full Name of MO
REM-OFF MINOR ping node-name/ip-address Remote Office
REM-OFF WARNING ping node-name/ip-address Remote Office
Table 8-427. Analog Line Error Log Entries
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
On/Off
Board Test to Clear Value
1(a) A ping test to
an endpoint
has failed
MINOR OFF ping
node-name/ip-address
257(b) See note
(b)
A keep alive
update
request has
exceeded the
time limit for
an endpoint
Log only OFF ping
node-name/ip-address