Maintenance Object Repair Procedure
555-233-142
8-876 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs if the LAP-D Connectivity test fails. If this test fails
repeatedly, a MINOR alarm is raised. This alarm indicates the failure to
establish a LAP-D link with the port and to send and receive test data over
that port. See the repair procedure for LAP-D Connectivity test (#558).
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
Table 8-371. PDATA Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
1
1. Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values used in
the set options command.
On/Off
Board Test to Clear Value
0
2
2. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
Any Any Any test port UUCSSpp sh r 1
1 (a) LAP-D Connectivity test
(#558)
MINOR ON test port UUCSSpp r 3
18 Busy Port WARNING OFF release port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp sh
257 (c)
513 (c)
779 (c)
1025 (d) Translation RAM Update MINOR ON see footnote (c)
1281 (e)
1793 (f) Port Local Loop-Around
test (#602)
MINOR ON test port UUCSSpp
2049 (g) System Port Connectivity
test (#603)
MINOR OFF test port UUCSSpp
3842*
3843*
3844*
37914 test port UUCSSpp sh l