PDATA-PT (Packet Data Line Port)
Issue 1 May 2002
8-879555-233-142
Table 8-372. Test #558 LAP-D Connectivity Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT The port is in use for a call. Use status data-module extension command to
determine when the port is available for testing.
1. Retry the command when the port is idle. The port may be forced to the
idle state by executing busyout port UUCSSpp. This command is
destructive causing every call and link associated with the port to be torn
down.
1137 ABORT The test link could not be created.
1. If the PDATA port is in an EPN, this is probably caused by Center Stage
maintenance interactions. The Center Stage includes the Switch Node
Interface (SNI), Expansion Interface (EI) and DS1C boards. Clear any
problems in these boards before continuing.
2. Retry at 1-minute intervals up to 3 times.
1139 ABORT The packet bus in this port network is out-of-service.
1. Retire the alarm associated with the packet bus. Please see the
maintenance section on the packet bus for details.
2. Retry the command when the alarm associated with the packet bus is
retired.
1141 ABORT The TN2312 IPSI circuit pack’s Packet Interface (PKT-INT) circuit is out of
service.
1. See the repair procedures for the PKT-INT circuit to put this circuit back
into service.
2. Retry the command when the alarm associated with the Packet Interface is
retired.
1144 ABORT The packet bus in the Processor Port Network (Network 1) is alarmed.
1. Retire the alarm associated with the packet bus in the Processor Port
Network. Please see the maintenance section on the packet bus for
details.
2. Retry the command when the alarm associated with the packet bus is
retired.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page