PDATA-PT (Packet Data Line Port)
Issue 1 May 2002
8-881555-233-142
Table 8-373. Test #602 PDATA Port Local Loop-Around Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT The port is in use for a call. Use status data-module extension command to
determine when the port is available for testing.
1. Retry the command when the port is idle. The port can be made idle by
executing the busyout port UUCSSpp command. This command is
destructive causing every call and link associated with the port to be torn
down.
1006 ABORT Port is out-of-service.
1. Run status data-module extension to check if the port is busied out. Run
release port UUCSS to free it, re-run the test.
2. See the PKT-BUS MO’s section, and fix any problems that are related to
the packet bus.
2000 ABORT Response to the test was not received for the PDATA circuit pack within the
allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2. reset board UUCSS if the other ports on the board are idle (amber LED is
off), or run the status data-module extension command.
3. Retry the command at 1-minute intervals up to 3 times.
4. Replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL The PDATA circuit pack has detected a failure in the execution of the test.
1. If the test fails 3 times, reset board UUCSS if the other ports on the board
are idle (amber LED is off), or run the status data-module extension
command.
2. If the test fails again, replace the circuit pack.
PASS The PDATA on-board loop-around test for the port has passed verifying the
integrity of the per-port circuitry.
Continued on next page